Recirculation from the pump discharge through a cyclone separator delivering the clean fluid to a cooler and then to the seal chamber. The solids are delivered to the pump suction line.
A Cyclone separator
B Cooler
C Temperature indicator
D Contaminated liquid IN
E Clean liquid OUT
F Separated liquid OUT
1 From cooler
2 Flush (F)
3 Quench (Q)
4 Drain (D)
5 Seal chamber
Example seal: EagleBurgmann H75VA4-S single pusher mechanical seal.
Key
TI Temperature indicator
1CW-FL, 1CW-FX, 2CW-CW, 2CW-CS, 3CW-FB, 3CW-BB, 3CW-FF
3NC-FB*, 3NC-BB*, 3NC-FF*
* Remark: The configurations listed for each individual piping plan are to be understood as recommendations including possible utilizations which may also be applied.
Follow the direct link to your API 682 4th ed. contact
Download the free EagleBurgmann API piping plan tool and benefit from useful and practical information
With our free e-mail newsletter „Excellence in Practice“, you will receive first-hand information about current products, services, references and worthwhile industry insights.
To enable you to make the best possible use of the contents of our website, we use so-called cookies.
By using the website, you agree to the use of cookies. Further information about the use of cookies and how you can object to the use of cookies can be found in our data protection information.
Data privacy statementThese cookies are absolutely necessary for the operation of the site and enable, for example, security-related functionalities.
To further improve our website, we collect anonymous data for statistics and analysis. With the help of these cookies we can, for example, determine the number of visitors and accesses to certain pages and optimise our content.