With around 250 locations and 90 serve centers, we are represented in the most important economic regions of the world. The advantages are clear: short paths to our customers, fast response times and a shared language.
Barrier fluid system pressurized by a piston accumulator supplying clean liquid for an arrangement 3 pressurized dual seal. The barrier pressure is generated from the seal chamber pressure. The system is self-energizing and reacts to fluctuations in the seal chamber fluid pressure.
A Cooler
B Piston accumulator
C Pressure reference
D Drain
E Vent
3 Pressure reference
4 Flush (F)
5 Liquid barrier OUT (LBO)
6 Liquid barrier IN (LBI)
7 Seal chamber
Example seal: EagleBurgmann MBS682-PTA dual metal bellows mechanical seal.
Key
1 Make-up barrier liquid
2 Piston accumulator
5 Liquid barrier OUT (LBO)
6 Liquid barrier IN (LBI)
8 Vent
9 Barrier fluid drain
LI Level indicator
LT Level transmitter
PRV Pressure relief valve*
PDIT Differential pressure transmitter with local indicator
TI Temperature indicator*
* If specified
** Vertically oriented, finned air cooler may be provided if specified
3CW-FB, 3CW-BB, 3CW-FF
Follow the direct link to your API 682 4th ed. contact
Download the free EagleBurgmann API piping plan tool and benefit from useful and practical information
With our free e-mail newsletter „Excellence in Practice“, you will receive first-hand information about current products, services, references and worthwhile industry insights.