With around 250 locations and 90 serve centers, we are represented in the most important economic regions of the world. The advantages are clear: short paths to our customers, fast response times and a shared language.
A containment seal chamber leakage collection system for condensing or mixed phase leakage on arrangement 2 unpressurized seals with containment seals.
A From mechanical seal
B To vapor collection system
C Drain
4 Flush (F)
5 Containment seal vent (CSV), plugged
6 Containment seal drain (CSD)
7 Gas buffer inlet (GBI), plugged unless used with a Plan 72
8 Seal chamber
Example seal: EagleBurgmann H75A4-C dual pusher mechanical seal.
Key
1 To vapor collection system
2 To liquid collection system
3 Test connection (if specified)
5 Containment seal vent (CSV), plugged
6 Containment seal drain (CSD)
7 Gas buffer inlet (GBI), plugged unless used with a Plan 72
LI Level indicator
LIT Level transmitter with local indicator
PIT Pressure transmitter with local indicator
* If specified
2CW-CS
Follow the direct link to your API 682 4th ed. contact
Download the free EagleBurgmann API piping plan tool and benefit from useful and practical information
With our free e-mail newsletter „Excellence in Practice“, you will receive first-hand information about current products, services, references and worthwhile industry insights.
To enable you to make the best possible use of the contents of our website, we use so-called cookies.
By using the website, you agree to the use of cookies. Further information about the use of cookies and how you can object to the use of cookies can be found in our data protection information.
Data privacy statementThese cookies are absolutely necessary for the operation of the site and enable, for example, security-related functionalities.
To further improve our website, we collect anonymous data for statistics and analysis. With the help of these cookies we can, for example, determine the number of visitors and accesses to certain pages and optimise our content.